CAT5 UTP Low Smoke Zero Halogen Network Cable
| Cat5e U/UTP Low Smoke, Zero Halogen Network Cable in 305 metre dispenserCat5e oxygen free copper twisted pair data cable with low smoke zero halogen sheath. Supplied in dispensing box and marked at 1 metre intervals. This cable is designed for high speed data transmission such as Gigabit Ethernet applications.  
	Low smoke zero halogen sheath material compliant to RoHS minimises the risk of thick black smoke and poisonous fumes in the event of a fire  
	AWG 24 oxygen free solid copper conductor  
	Supplied in an easy-pull dispensing box  
	Passes Cat5e fluke test 100m at 100MHz  
	Complies to TIA/EIA-568 Cat5e standard  
	HDBaseT Compliant  
	Specification  
	Conductor Solid OFC  
	Strands 8 x 1/0.  
	Conductor CSA 8 x 0.196mm  
	Cable : diameter 5mm  
	Insulation HDPE 0.19mm thickness  
	Sheath LSZH 0.5mm thickness  
	Capacitance 4.9nF/100m  
	DC resistance @ 20°C <9.5 ohms/100m  
	Impedance (1 to 100MHz) 100±15 ohms  
	Return loss >20dB @100m | 
£115.50
(inc VAT £138.60)CAT5E Pure Oxygen Free Copper Cable. Sold in 305 Metre Dispenser
| CAT5E Pure Oxygen Free Copper U/UTP High Quality Data Network Cable
  
	Oxygen free copper twisted pair data cable supplied in dispensing box and marked at 1 metre intervals.  
  
	This cable is designed for high speed data transmission up to Gigabit Ethernet applications. 
  
	AWG 24 oxygen free solid copper conductor 
  
	Supplied in an easy-pull dispensing box 
  
	Passes Cat5e fluke test 100m at 100MHz 
  
	Complies to TIA/EIA 568 Cat5e standard 
  
	Conductor: Solid OFC 
  
	Strands: 8 x 1/0.5mm 
  
	Cable diameter: 5mm 
  
	Insulation: HDPE 0.19mm thickness 
  
	Sheath: PVC 0.5mm thickness 
  
	Capacitance: 4.9nF/100m 
  
	DC resistance @ 20C: 16.7 Ohms/100m 
  
	Impedance (1 to 100MHz)100 Ohms 
  
	Return loss Less than 20dB @100m 
  
	Attenuation Less than 22dB @100m 
  
	NEXT: Greater than 35.3dB 
  
	PSNEXT Greater than 32.3dB 
  
	ELFEXT Greater than 23.8dB 
  
	PSELFEXT: Greater than 20.8dB 
  
	Phase delay: Less than 570ns 
  
	Cable colour: Grey 
  
	Length: 305m 
  
	Weight: 8.6kg | 
£105.00
(inc VAT £126.00)CAT6 Outdoor Pure Oxygen Free Copper Conductors in 1 metre marked 305 Metre Dispenser
| Cat6e U/UTP Outdoor Pure Oxygen Free Copper OFC Network Cable  
	Cat6 pure oxygen free copper (OFC) twisted pair data cable with LDPE sheath, supplied in dispensing box and marked at 1 metre intervals. This cable is designed for high speed data transmission such as Gigabit Ethernet applications in an outdoors environment. 
 | 
£165.00
 
                
                                  £135.00
(inc VAT £162.00) 18% OffCAT6 Outdoor Pure Oxygen Free Copper Conductors in 100 Metre Dispenser
| Cat6e U/UTP Outdoor Pure Oxygen Free Copper OFC Network Cable  
	Cat6 pure oxygen free copper (OFC) twisted pair data cable with LDPE sheath, supplied in 100M dispensing box. This cable is designed for high speed data transmission such as Gigabit Ethernet applications in an outdoors environment. 
 | 
£74.00
(inc VAT £88.80)CAT6 Oxygen-Free Copper Cable. Sold in 100 Metre Dispenser
| CAT6 Oxygen-Free Copper (OFC) High Speed Twisted pair Data Cable  
		Supplied in a 100m dispensing box. This cable is designed for high speed data transmission such as Gigabit Ethernet applications  
		OFC Oxygen free solid copper conductor  
		Supplied in an easy-pull dispensing box  
		Passes Cat6 fluke test 100m at 250MHz  
		Specification:  
		ConductorSolid Oxygen Free Copper  
		Strands 8 x 1/0.54mm  
		Conductor CSA 8 x 0.229mm  
		Cable diameter 5.8mm  
		InsulationHDPE 0.195mm thickness  
		SheathPVC 0.55mm thickness  
		Capacitance 5.2nF/100m  
		DC resistance @ 20°C less than 9.5 ohms/100m  
		Impedance (1 to 250MHz)100 ohms  
		Return loss>17.3dB @100m | 
£63.50
(inc VAT £76.20)CAT6 Oxygen-Free Copper Cable. Sold in 305 Metre Dispenser
| CAT6 Oxygen-Free Copper (OFC) High Speed Twisted pair Data Cable  
		Supplied in dispensing box and marked at 1 metre intervals. This cable is designed for high speed data transmission such as Gigabit Ethernet applications  
		OFC Oxygen free solid copper conductor  
		Supplied in an easy-pull dispensing box  
		Passes Cat6 fluke test 100m at 250MHz  
		Specification:  
		ConductorSolid Oxygen Free Copper  
		Strands 8 x 1/0.54mm  
		Conductor CSA 8 x 0.229mm  
		Cable diameter 5.8mm  
		InsulationHDPE 0.195mm thickness  
		SheathPVC 0.55mm thickness  
		Capacitance 5.2nF/100m  
		DC resistance @ 20°C less than 9.5 ohms/100m  
		Impedance (1 to 250MHz)100 ohms  
		Return loss>17.3dB @100m | 
£140.00
 
                
                                  £125.00
(inc VAT £150.00) 11% OffCAT6 U/UTP Low Smoke Zero Halogen Network Cable
| CAT6 U/UTP LOW SMOKE, ZERO HALOGEN, OXYGEN-FREE COPPER NETWORK CABLE - PER 305 METRE DISPENSER 
	Very High Quality Copper  
	This cable is designed for high speed data transmission such as Gigabit Ethernet applications.  
	Low smoke zero halogen sheath material compliant to RoHS minimises the risk of thick black smoke and poisonous fumes in the event of a fire.  
	Specs  
	Oxygen free solid copper conductor  
	Supplied in an easy-pull dispensing box  
	Passes CAT6 fluke test 100m at 250MHz  
	Complies to TIA/EIA-568 Cat6 standard  
	Conductor Solid OFC  
	Strands8 x 1/0.54mm  
	Conductor CSA 8 x 0.229mm2  
	Cable diameter 5.8mm  
	InsulationHDPE 0.195mm thickness  
	SheathLSHF 0.55mm thickness  
	Capacitance 5.2nF/100m  
	DC resistance @ 20 deg C Less than 9.5 ohms/100m  
	Impedance (1 to 250MHz)100 Plus/Minus 15 ohms  
	Return loss Less than 17.3dB @100m  
	Attenuation Less than 32.8dB @100m  
	Cable colour Mauve  
	Length 305m  
	Weight 12.7kg | 
£155.00
 
                
                                  £135.00
(inc VAT £162.00) 13% OffCAT6A S/FTP Low Smoke Zero Halogen Network Cable
| CAT6A S/FTP Low Smoke, Zero Halogen Oxygen Free Copper (OFC) Data Network Cable in 305m Reel 
 Very High Quality Copper 
  
	CAT6A oxygen free copper twisted pair data cable with low smoke zero halogen sheath and individual pair aluminium foil screen. Supplied on a wooden drum reel and marked at 1 metre intervals. This cable is designed for high speed data transmission such as Gigabit Ethernet applications. 
  
	AWG 23 oxygen free solid copper conductor 
  
	 | 
£215.00
 
                
                                  £200.00
(inc VAT £240.00) 7% OffCAT6A U/FTP Low Smoke Zero Halogen Network Cable
| CAT6A U/FTP Low Smoke, Zero Halogen Oxygen Free Copper (OFC) Data Network Cable in 305m Dispenser Box 
	Very High Quality Copper  
	CAT6A oxygen free copper twisted pair data cable with low smoke zero halogen sheath and individual pair aluminium foil screen. Supplied on a wooden drum reel and marked at 1 metre intervals. This cable is designed for high speed data transmission such as Gigabit Ethernet applications.  
	Low smoke zero halogen sheath material compliant to RoHS minimises the risk of thick black smoke and poisonous fumes in the event of a fire  
	AWG 23 oxygen free solid copper conductor  
	Supplied on a sturdy wooden drum reel  
	Passes Cat6a fluke test 100m at 500MHz  
	Complies to TIA/EIA-568 Cat6a standard  
	Specs  
	Conductor - Solid OFC  
	Strands - 8 x 1/0.565mmØ ±2%  
	Conductor CSA - 8 x 0.251mm²  
	Cable diameter - 7.5mmØ  
	Screen - Aluminium foil  
	Insulation - PE 0.385mm thickness  
	Sheath - LSZH 0.55mm thickness  
	Capacitance - 6.6nF/100m  
	DC resistance @ 20°C - <7.8 Ohms/100m  
	Impedance (1 to 250MHz) - 100±15 Ohms  
	Impedance (250 to 500MHz) - 100±22 Ohms  
	Return loss - >25dB @100m  
	Attenuation - <45.3dB @100m  
	NEXT - >74.3dB  
	PSNEXT - >72.3dB  
	ELFEXT - >14dB  
	PSELFEXT - >11dB  
	Phase delay - <570ns  
	Cable colour - Lilac  
	Length - 305m  
	Weight - 14.5kg | 
£215.00
 
                
                                  £190.00
(inc VAT £228.00) 12% OffOutdoor Solid Pure Oxygen Free Copper Conductors in 305 Metre Dispenser
| Cat5e U/UTP Outdoor Pure Oxygen-Free Copper Network CableCat5e oxygen free copper twisted pair data cable with LDPE sheath. Supplied in dispensing box and marked at 1 metre intervals. This cable is designed for high speed data transmission such as Gigabit Ethernet applications. 
  
			  
			Conductor                            Solid Oxygen Free Copper 
 
 | 

 